Pipe Flow

Pipe Flow

NOTE: Program selects pipe sizes and
design conditions primarily on Full-Flow.
Input Data:
Design Flow = cfs
Pipe Slope = ft/ft
Mannings 'n' =
Results:
Diameter = in
Percent full = %
   

Results:

*********INPUT DATA*********

DESIGN FLOW = 10 CFS

PIPE SLOPE = 0.02 FT/FT

MANNING'S ROUGHNESS COEF. = 0.012

**********PIPE SIZE***********

PIPE DIAMETER = 18 INCHES

****PARTIAL FLOW CONDITION****

DEPTH OF FLOW = 0.86 FT

VELOCITY = 9.6 FPS

****FLOWING FULL CONDITION****

MINIMUM REQURIED SLOPE = 0.0078 FT/FT

FLOWING FULL VELOCITY = 5.66 FPS